Water Treatment Chemicals

Boiler Water Treatment Chemicals:
Corrosion is significant problem in boilers. It is estimated that problems due to boiler system corrosion cost industry billions of dollars per year.Because of that, preventing corrosion is a must for industry. According to this, Navi Chemicals has improved the most efficient chemicals which includes DEHA or Catalyzed Sulfite as an oxygen absorbent for preventing corrosion in steam boilers.

Oxygen Scavengers:
Dissolved oxygen can cause several types of problem in steam generating boilers but the major one is corrosion. Due to this, Navi Chemicals has improved the most efficient chemicals which includes DEHA or Catalyzed Sulfide as an oxygen scavenger for preventing corrosion in steam boilers.

Dispersants:
Suspended solids which occur in the feedwater should have prevented from the steam boiler before it makes scale, by blowdown. Because, the dissolved solids such as total hardness can form as a scaling on the surface of steam boiler and it can cause unscheduled downtime. Due to this, preventing the deposition in the steam boiler is vital. So, Navi Chemicals has improved the most efficient chemicals which includes Polymers, Phosphate and Phosphonate.

Condensate Return Lines Inhibitors:
Condensate return lines can cause carbonic acid corrosion. Due to this, Navi Chemicals developed high concentrated chemicals which includes neutralizing amines and filming amines. Also, Navi Chemicals have been used another type of solution which includes three different neutralizing amines in the product for protecting the system against corrosion.

Combined Products:
Combined products which includes oxygen scavengers, antiscalants and condensate return line inhibitors for small and medium capacity boilers.

Products:
HidroFlex 2100: Based on catalyzed sulfite and should use to remove oxygen from boilers.
HidroFlex 2176: Should use as dispersant and antiscalant in boilers.
HidroFlex 2200: Based on sulfite which should use as a corrosion and scale inhibitor in boilers.
HidroFlex 2290: Based on neutralizing amine mixtures and should use for short, medium and long pipe lines to prevent carbonic acid corrosion.
HidroFlex 2420: Should use for preventing corrosion, scale and condensate return lines corrosion with multi-functional mixture. (Consists DEHA)

Cooling Tower Chemicals:
In cooling systems corrosion causes two major problems the first one is the failure of the equipment with the result of a cost problem and plant downtime. The second one and most obvious is the plant efficiency due to loss of heat transfer. According to this, Navi Chemicals has improved corrosion and scale Inhibitors which includes organic and inorganic inhibitors to prevent corrosion and scale in cooling towers.
These inhibitors are highly effective on whole metals but much more effective against copper and iron alloys. Also, Navi Chemicals products are effective on active corrosion cells which already occur in the system.
Organic and inorganic inhibitors can work in extreme conditions such as high concentrated hard water. Also, there is no requirement to dose acids. Products do not contain heavy metals which seriously harms environment.

Biocides:
Navi Chemicals developed biocides which effects on microbiologic organisms such as legionella. Our biocides can work both acidic and alkaline conditions.

Products:
HidroFlex 1040: Based on all organic chemicals which protects cooling tower against scale and corrosion.
HidroFlex 1409: Provides highly effective corrosion and scale protection in softened water systems.
HidroFlex 1810: Should use as dispersant in cooling towers.
HidroFlex 1880: Provides highly effective corrosion and scale protection.
HidroFlex 4160: Based on isotiazolin as a non-oxidizing biocide.
HidroFlex 4320: Based on QAC as a non-oxidizing biocide.

Closed System Chemicals:
Navi Chemicals has improved corrosion and scale inhibitors which includes organic and inorganic inhibitors to prevent corrosion and scale in both cooling and heating closed system circulations. Inhibitors makes molecular film between water and surface of the metal to prevent corrosion in the circulation system. To maintain the molecular film inhibitors should present in the system consistently. Navi Chemicals has also improved inhibitors which especially works on an aluminum surfaces.

Products:
HidroFlex 1720: Closed system corrosion inhibitor with nitrite.
HidroFlex 1750: Closed system corrosion inhibitor both nitrite and molybdate.
HidroFlex 1770: Closed system corrosion inhibitor with molybdate.

Domestic Water Chemicals:
Navi Chemicals has improved corrosion and deposition inhibitors for Hospitals, hotels, plazas, universities and big compounds which uses in domestic water lines. According to field experiences after inhibitor usage, neither corrosion nor deposition have observed in systems.

Products:
HidroFlex 1860: Based on polyphosphate.
HidroFlex 1871: Based on silicate and polyphosphate.

Membrane Chemicals:
Preventing the scaling and deposition in reverse-osmosis membranes is vital for membranes. Because of that, Navi Chemicals has enhanced scale inhibitors which includes polymers and dispersants.

Products:
HidroFlex 9001: Effective on calcium carbonate, sulfate and iron compounds.
HidroFlex 9005: Effective on high silica and calcium compounds.

Chemical Cleaning and Passivation:

Chemical Cleaning Products:
Using hard water can cause deposit in pipelines and in closed systems. Due to this, Navi Chemicalshas improved highly concentrated chemicals with inhibitors to clean deposition.

Passivation Chemicals:
Right after the montage of the new system, deposition and dirt can occur in the pipelines. Because of that, Navi Chemicals has enhanced acidic and polymeric chemicals to prevent the dirt and deposition.

Resin Cleaning Chemicals:
During water softening process, organic and inorganic ions and impurities can occur in the resin. Because of that, cleaning the resin is a must in the water softening systems. According to this Navi Chemicals has developed the chemical which should apply for preventing dirt occurrence in the softening column. By the way, this application can apply without disassembling the softening column.

Neutralizers:
After acidic cleaning, neutralizing the system water is a must. Navi Chemicals has improved neutralizers for this.

Acid Inhibitors:
During the acidic cleaning, protecting the metal against corrosion is vital for the system. Because of that, Navi Chemicals offers you the acid inhibitors to protect system against corrosion.